DC INPUT MULTIPLY/DIVIDE TRANSMITTERS
PLUG-IN MODULES, FIXED RANGE

JH4410I: Output = AxB, Input/Output Isolated
JH4420I: Output = A/B, Input/Output Isolated
The JH4410/4420 Series offers DC outputs representing the product or quotient of two DC
inputs. Input and output ranges need not be the same; for example, the inputs could be 0/10Vdc while the
output could be 4/20mA. These are fixed-range devices, precisely calibrated to your specified ranges at the
factory.
Red-green Quick-Check LEDs give a quick indication of the relative output. Red is brighter
at the low end, green at high, while at mid-scale both are approximately equal. Red-only indicates offscale
low while green-only indicates offscale high.
Input/output isolation is standard. (The inputs are not
isolated from each other.) Available options include, AC or DC power
choices and reverse-action Option RT (decreasing output with increasing input).
UNDERSTANDING THE INPUT FUNCTIONS
Standard calibration calculates the inputs and output on a percent-of-span basis. For
example, for Output = AxB with a 4/20mA input range and 0/10V output range, if both inputs are at 50% (12mA)
the output will be 25% (0.5 x 0.5 = 0.25), or 2.5 volts.
Nonstandard calibrations are available, including dissimilar input ranges and
input-to-output offsets. We also are able to provide Output = (AxB)/C in one unit. Please contact us with
your special requirements.
ORDERING INFORMATION
|
Model Number: |
Select your model number from the list above. Add
suffix –AC for AC power or –DC for DC power.
|
|
Input Range: |
Specify any DC voltage or current range allowed by
the "Input Capabilities" spec, below.
|
|
Output Range: |
Specify any DC voltage or current range allowed by
the "Output Capabilities" spec, below.
|
|
Power: |
Specify 115Vac, 230Vac, 12Vdc or 24Vdc.
|
|
Reverse-Acting Transmitter (decreasing output with increasing
input function): |
Specify Option RT.
|
|
Loop-Powered Output: |
4/20mA "current sink" output stage
for connection to devices whose inputs provide 24Vdc loop excitation. Specify Option LPO.
|
Urethane Coating: |
Specify Option "U"
|
INSTALLATION AND CONNECTIONS
These transmitters plug into any standard 8-pin circular ("octal") relay socket.
JH Technology offers a socket suitable for DIN-rail or surface mounting
(see the Accessories page). Pin connections are:
Pin 1: Power (AC or, if DC power option, DC plus).
Pin 2:
No connection.
Pin 3: Power (AC or, if DC power option, DC minus).
Pin 4: B input (plus).
Pin
5: A input (plus).
Pin 6: Input common (minus).
Pin 7: Output plus.
Pin 8: Output
minus.
DETAILED SPECIFICATIONS
|
Voltage Input Capabilities: |
100mV minimum span, +/-20V maximum
input. Offset ranges are allowed.
(Input Impedance: 200kohms or greater.)
|
|
Current Input Capabilities: |
1mA minimum span, +/-100mA maximum
input. Offset ranges are allowed.
(Input Resistance: Varies with input range. Contact factory for details. 62 ohms for 4/20mA
input.)
|
|
Voltage Output Capabilities: |
1 volt minimum output span, -10 to
+15V absolute limit. Offset ranges are allowed. Maximum output load, 10mA (1Kohm at 10V output).
|
|
Current Output Capabilities: |
1mA minimum output span, 0 to +25mA
absolute limit. Positive offsets are allowed, negative outputs are not. Output drive capability, 24V (1,200
ohms max. at 20mA output).
|
|
Accuracy (factory calibration): |
+/-0.2% of span or better.
(For divider, applies when inputs are greater than 10% of span). |
| Adjustability: |
Zero and span each are adjustable approx. +/-15%
of span.
|
|
Response Time: |
Under 100 milliseconds.
|
|
Isolation:
|
Power, 1,500Vac rms (2,100V peak). Input/Output 1,000Vac rms
(1,400V peak). Note: The inputs are not isolated from each other.
|
|
Guaranteed Operating Temperature: |
-10 to +60 deg. C (14 to 140
deg. F).
|
|
Temperature Stability: |
+/-0.02% of span per deg. C, or better.
|
|
Power Requirements: |
AC, 115 or 230Vrms, 50/60Hz, 2.5V-A. DC, 12
or 24V, 2.5W.
|