STRAIN GAUGE (BRIDGE) INPUT TRANSMITTERS
PLUG-IN MODULE, FIXED RANGE

JH4051I: Strain Gauge Input, Input/Output Isolated

    • Input Spans as low as 0.4mV/V (at 10V excitation)
    • Excitation Adjustable from 4 to 12V
    • Quick-Check Red/Green Output LEDs
    • Uses Standard 11-Pin Socket
    • Nonstandard Ranges Available
    • AC or DC Power Options

     

    JH4051I
    PDF
    DATA SHEET

Model JH4051I supplies DC excitation to a strain gauge or other resistance bridge, amplifies the bridge output and provides a proportional DC voltage or current. A fixed-range device, it is precisely calibrated to your specified range at the factory. 

Red-green Quick-Check LEDs give a quick indication of the relative output. Red is brighter at the low end, green at high, while at mid-scale both are approximately equal. Red-only indicates offscale low while green-only indicates offscale high.

Available options include AC or DC power choices and reverse-action Option RT (decreasing output with increasing input).

ORDERING INFORMATION

Model Number

Select JH4051I-AC for AC power, JH4051I-DC for DC power.

Bridge Excitation

Specify any voltage between 4 and 12Vdc. Will be factory set to 10V if not specified on your order. User-adjustable. (Note: 40mA maximum load. For 120ohm bridges, specify 4.8V or less.)

Input Range Specify any input range allowed by the "Input Capabilities" spec, below. Specify either as millivolts per volt, or as millivolts. (Millivolts equals millivolts-per-volt multiplied by the excitation voltage. For example, 0-2.0 mV/V at 10V excitation equals 0-20mV.)
Output Range

Specify any DC voltage or current range allowed by the "Output Capabilities" spec, below.

Power

Specify 115Vac, 230Vac, 12Vdc or 24Vdc.

Reverse-Acting Transmitter (decreasing output with increasing input)

Specify Option RT.

Loop-Powered Output

4/20mA "current sink" output stage for connection to devices whose inputs provide 24Vdc loop excitation. Specify Option LPO.

INSTALLATION AND CONNECTIONS

The JH4051I plugs into any standard 11-pin circular ("octal") relay socket. JH Technology offers two sockets: DS011 for DIN-rail or surface mounting and ST011 for Snap-Track mounting (see the Accessories page). Pin connections are:

Pin 1: Power (AC or, if DC power option, DC plus).
Pin 2: No connection.
Pin 3: Power (AC or, if DC power option, DC minus).
Pin 4: Input plus (bridge output).
Pin 5: Input minus (bridge output).
Pin 6:  No Connection 
Pin 7: Bridge excitation plus.
Pin 8: Bridge excitation minus.
Pin 9: Output plus.
Pin 10: Output minus.
Pin 11: No connection.

DETAILED SPECIFICATIONS

Input Capabilities:

4mV minimum span (0.4mV/V at 10V excitation). 10V maximum span (1V/V at 10V excitation). Offset ranges are allowed.
(Input Impedance: 200kohms.)

Excitation Voltage:  

Adjustable from 4 to 12Vdc. 40mA maximum load. Factory set to 10Vdc unless otherwise specified. (Note: 120 ohm bridges limited to 4.8V or less. 350 ohm bridges are ok to 12V.)

Voltage Output Capabilities:  

1 volt minimum output span, -10 to +15V absolute limit. Offset ranges are allowed. Maximum output load, 10mA (1Kohm at 10V output).

Current Output Capabilities:  

1mA minimum output span, 0 to +25mA absolute limit. Positive offsets are allowed, negative outputs are not. Output drive capability, 24V (1,200 ohms max. at 20mA output).

Accuracy (factory calibration):  

+/-0.1% of span or 10 microvolts, whichever is greater.

Adjustability:  

Zero and span each are adjustable approx. +/-15% of span.

Linearity:  

+/-0.05% of span or better.

Response Time:  

Under 100 milliseconds.

Isolation:  

Power, 1,500Vac rms (2,100V peak). Input/Output, 1,000Vac rms (1,400V peak).

Guaranteed Operating Temperature:  

-10 to +60 deg. C (14 to 140 deg. F).

Temperature Stability:  

+/-(0.02% of span plus 1.3 microvolts) per deg. C, or better.

Power Requirements:  

AC, 115 or 230Vrms, 50/60Hz, 2.5V-A. DC, 12 or 24V, 2.5W.

 

 
Top of page Listing by product number Home page Contact us