• Home
  • Transmitters
    • DIN RAIL
      • DC Input
        • JH5000 (Spans greater than 1V)
        • JH5070 (Spans less than 1V)
        • JH5030 (4/20mA in)
        • JH5040 (4/20mA w/loop supply)
        • JH5050 (4/20mA isolator)
        • JH5060 (other Current inputs)
        • JH5080 (rangeable)
      • Math(Logic)
        • JH5110 (DC 2-Input Add)
        • JH5120 (DC 3-Input Add)
        • JH5130 (DC 2-Input Subtract)
        • JH5140 (DC 2-Input Multiply)
        • JH5150 (DC 2-Input Divide)
        • JH5160 (DC Square)
        • JH5170 (DC Square Root)
      • Temperature
        • Thermocouple
          • JH5200 (Standard)
          • JH5210 (Linearized)
        • RTD
          • JH5400 (Platinum, Copper, Nickel)
      • Strain Gauge
        • JH5500 (Bridge Input)
      • AC Input
        • JH5600 (Standard)
        • JH5610 (True RMS)
      • Frequency
        • JH5700
      • Potentiometer
        • JH5800
    • PLUG-IN
      • DC Input
        • JH4300 (Voltage & Current)
        • JH4300C (4/20mA Isolator)
        • JH4305 (4/20mA w/loop supply)
        • JH4380W (Rangeable)
      • Math(Logic)
        • JH440xI (Add or Subtract)
          • JH4400I: Output = (A+B+C+D)/4
          • JH4401I: Output = (A+B+C)/3
          • JH4402I: Output = (A+B)/2
          • JH4408I: Output = A-B
        • JH4410I (DC Multiply)
        • JH4420I (DC Divide)
        • JH4430I (DC Square)
        • JH4440I (DC Square Root)
      • Temperature
        • Thermocouple
          • JH4130 (Standard)
          • JH4130L (Linearized)
        • RTD
          • JH4001I (Platinum, Copper, Nickel)
      • Strain Gauge
        • JH4051I (Bridge Input)
      • AC Input
        • JH6010I (Voltage)
        • JH6010IR (True RMS Voltage)
        • JH6020I (Current)
        • JH6020IR (True RMS Current)
      • Frequency
        • JH7010I
      • Potentiometer
        • JH4003I
    • Two Wire
      • DC Input
        • JH200
      • Thermocouple
        • JH220 (Fixed)
        • JH225 (Rangeable)
      • RTD
        • JH240 (Fixed)
        • JH245 (Rangeable)
      • Potentiometer
        • JH250
    • Pulse & Frequency
      • Integrator
        • JH7500 (DC to Frequency)
        • JH7501 (DC to Low Pulse/Relay Out)
      • Transmitter
        • JH7580 (Rangeable, Plug-In)
        • JH7010I (Fixed, Plug-In)
        • JH5700 (Fixed, DIN Rail)
      • Alarm
        • JH1700 (Single)
        • JH1720 (Dual)
      • Pulse
        • Amplifier
          • JH376 (Dual Channel)
        • Converter
          • JH377 (Dual Channel)
        • Conditioner
          • JH2376 (Full Feature, DIN Rail)
    • Field Mount Transmitters
      • DC Input
        • FDT5000 (Spans greater than 1V)
        • FDT5070 (Spans less than 1V)
        • FDT5030 (4/20mA in)
        • FDT5040 (4/20mA w/loop supply)
        • FDT5060 (other Current inputs)
      • Math(Logic)
        • FDT5110 (DC 2-Input Add)
        • FDT5120 (DC 3-Input Add)
        • FDT5130 (DC 2-Input Subtract)
        • FDT5140 (DC 2-Input Multiply)
        • FDT5150 (DC 2-Input Divide)
      • Temperature
        • Thermocouple
          • FDT5210 (Linearized)
        • RTD
          • FDT5400 (Platinum, Copper, Nickel)
      • Strain Gauge
        • FDT5500 (Bridge Input)
      • AC Input
        • FDT5600 (Standard)
        • FDT5610 (True RMS)
      • Potentiometer
        • FDT5800
  • Custom
    • Custom & OEM
    • Specials/Mods
    • MiniSystems
    • Control Panels
  • Alarms
    • Single
      • DC Input
        • JH1005 (4/20mA w/loop supply)
        • JH1000 (Standard)
      • Temperature
        • Thermocouple
          • JH1200
        • RTD
          • JH1400 (Platinum, Copper, Nickel)
      • Strain Gauge
        • JH1500 (Bridge Input)
      • AC Input
        • JH1600
        • JH1600R (True RMS)
      • Frequency
        • JH1700
      • Potentiometer
        • JH1800
    • Dual
      • DC Input
        • JH1020 (Standard)
        • JH1025 (4/20mA w/loop supply)
      • Temperature
        • Thermocouple
          • JH1220
        • RTD
          • JH1420 (Platinum, Copper, Nickel)
      • Strain Gauge
        • JH1520 (Bridge Input)
      • AC Input
        • JH1620
        • JH1620R (True RMS)
      • Frequency
        • JH1720
      • Potentiometer
        • JH1820
  • Accessories
  • Application Notes
  • Product Listing
  • Blog
  • Contact
Tuesday, 31 May 2011 01:54 Last Updated on Monday, 29 August 2011 01:08 Written by Administrator

MODEL JH225: 2-WIRE TRANSMITTER
THERMOCOUPLE INPUT, USER-RANGEABLE, NONISOLATED

    • Thermocouple Types J, K and T
    • Input Ranges as Low as 2mV
    • Low-Drift Input Amplifier
    • Fits Standard Connection Heads
    • -40 to +80 Degree C Operation
    • DIN Rail mounting available

    JH225
    PDF
    DATA SHEET

    JH225
    PDF
    CAL INSERT

The Model JH225 2-wire transmitter provides a 4/20mA current loop output proportional to the input from a thermocouple. 16-position Zero and Span switches plus fine-adjust trimpots allow recalibration over a wide range of gains and offsets. Types J, K or T thermocouples may be selected. Cold junction compensation is located in the terminal block for optimum accuracy. Conformal coating protects the circuitry against condensation and corrosion in industrial atmospheres. Upscale burnout indication is standard.

The JH225 is a loop-powered device. Connected in series between a 24Vdc supply and readout instruments, it receives its power from the 4/20mA output loop. A built-in LED indicates loop current: dim at 4mA, bright at 20mA. The JH225 does not provide input/output isolation.

For a fixed range, factory-calibrated 2-wire thermocouple transmitter capable of handling all standard thermocouple types see Model JH220.

ORDERING INFORMATION

Model Number: 

Model JH225.

Input Range: 

The JH225 is normally shipped tested but uncalibrated. If you would like us to calibrate it simply specify on your order. We’ll do so at no extra charge. Specify thermocouple type J, K or T and specify any input range allowed by the "Input Capabilities" spec, below.

T/C Burnout Indication:  

(Always upscale – offscale high.)

Output Range: 

(Always 4/20mAdc.)

Power: 

(Always dc loop powered.)

DIN-Rail Mounting:  

Change model number to Model JH225-DIN. (See "Installation and Connections," below.)

INSTALLATION AND CONNECTIONS

The JH225 is 1-3/4 inches in diameter and is designed to fit many standard thermocouple-type connection heads. It may also be mounted to any surface using two #8 (or smaller) screws. An optional DIN-rail mounting clip (specify Model JH225-DIN) allows the transmitter to be snapped onto DIN rail. Width is 1-3/4 inches.

Connections are made to the transmitter’s terminal strip. Connections are:

"+" Terminal: Output/Power Loop. Receives current from (+) DC supply. 
"-" Terminal:
Output/Power Loop. Passes on current to the next series loop device, or to the (-) supply. 
Terminal A:
Thermocouple plus. 
Terminal B:
No connection – compensator is encapsulated in this position. 
Terminal C:
Thermocouple minus. (On most thermocouples, the red wire is minus.)

DETAILED SPECIFICATIONS

Input Capabilities:  

Span may be set anywhere from 2mV to 60mV. Low end (zero) may be set as follows: Type J, -210 to +340 deg. C. Type K, -270 to +520 deg. C. Type T, -270 to +400 deg. C.

Input Thermocouple Types:  

May be set for use with types J, K or T.

Thermocouple Burnout Indication:  

Output goes offscale high (above 20mA).

Output:  

4/20mA, 2-wire (loop-powered) output.

Accuracy (if properly calibrated): 

+/-0.1% of span or 10 microvolts, whichever is greater.

Adjustability: 

Sufficient to achieve all specified input ranges.

Linearity: 

Linear with millivolts. Does not linearize the thermocouple.

Response Time: 

Under 100 milliseconds.

Guaranteed Operating Temperature: 

-40 to +80 deg. C (-40 to +176 deg. F).

Temperature Stability: 

+/-(0.02% of span plus 1 microvolt) per deg. C, or better.

Power Requirements: 

DC loop-powered. Requires at least 12Vdc at the transmitter’s output terminals. 36Vdc maximum.

Email Newsletter icon, E-mail Newsletter icon, Email List icon, E-mail List icon Sign up for our Email Newsletter

Latest News

  • Home
  • Transmitters with 1 millisecond response time
  • Custom Designs
  • Simple Special: Y = 1/X
  • Model JH2376 Pulse Conditioner
JH TECHNOLOGY, 5107 Lena Rd, Unit 111 Bradenton, FL  34211  USA
Toll Free 800.808.0300  Local 941.758.7710  Fax 941.758.7709