• Home
  • Transmitters
    • DIN RAIL
      • DC Input
        • JH5000 (Spans greater than 1V)
        • JH5070 (Spans less than 1V)
        • JH5030 (4/20mA in)
        • JH5040 (4/20mA w/loop supply)
        • JH5050 (4/20mA isolator)
        • JH5060 (other Current inputs)
        • JH5080 (rangeable)
      • Math(Logic)
        • JH5110 (DC 2-Input Add)
        • JH5120 (DC 3-Input Add)
        • JH5130 (DC 2-Input Subtract)
        • JH5140 (DC 2-Input Multiply)
        • JH5150 (DC 2-Input Divide)
        • JH5160 (DC Square)
        • JH5170 (DC Square Root)
      • Temperature
        • Thermocouple
          • JH5200 (Standard)
          • JH5210 (Linearized)
        • RTD
          • JH5400 (Platinum, Copper, Nickel)
      • Strain Gauge
        • JH5500 (Bridge Input)
      • AC Input
        • JH5600 (Standard)
        • JH5610 (True RMS)
      • Frequency
        • JH5700
      • Potentiometer
        • JH5800
    • PLUG-IN
      • DC Input
        • JH4300 (Voltage & Current)
        • JH4300C (4/20mA Isolator)
        • JH4305 (4/20mA w/loop supply)
        • JH4380W (Rangeable)
      • Math(Logic)
        • JH440xI (Add or Subtract)
          • JH4400I: Output = (A+B+C+D)/4
          • JH4401I: Output = (A+B+C)/3
          • JH4402I: Output = (A+B)/2
          • JH4408I: Output = A-B
        • JH4410I (DC Multiply)
        • JH4420I (DC Divide)
        • JH4430I (DC Square)
        • JH4440I (DC Square Root)
      • Temperature
        • Thermocouple
          • JH4130 (Standard)
          • JH4130L (Linearized)
        • RTD
          • JH4001I (Platinum, Copper, Nickel)
      • Strain Gauge
        • JH4051I (Bridge Input)
      • AC Input
        • JH6010I (Voltage)
        • JH6010IR (True RMS Voltage)
        • JH6020I (Current)
        • JH6020IR (True RMS Current)
      • Frequency
        • JH7010I
      • Potentiometer
        • JH4003I
    • Two Wire
      • DC Input
        • JH200
      • Thermocouple
        • JH220 (Fixed)
        • JH225 (Rangeable)
      • RTD
        • JH240 (Fixed)
        • JH245 (Rangeable)
      • Potentiometer
        • JH250
    • Pulse & Frequency
      • Integrator
        • JH7500 (DC to Frequency)
        • JH7501 (DC to Low Pulse/Relay Out)
      • Transmitter
        • JH7580 (Rangeable, Plug-In)
        • JH7010I (Fixed, Plug-In)
        • JH5700 (Fixed, DIN Rail)
      • Alarm
        • JH1700 (Single)
        • JH1720 (Dual)
      • Pulse
        • Amplifier
          • JH376 (Dual Channel)
        • Converter
          • JH377 (Dual Channel)
        • Conditioner
          • JH2376 (Full Feature, DIN Rail)
    • Field Mount Transmitters
      • DC Input
        • FDT5000 (Spans greater than 1V)
        • FDT5070 (Spans less than 1V)
        • FDT5030 (4/20mA in)
        • FDT5040 (4/20mA w/loop supply)
        • FDT5060 (other Current inputs)
      • Math(Logic)
        • FDT5110 (DC 2-Input Add)
        • FDT5120 (DC 3-Input Add)
        • FDT5130 (DC 2-Input Subtract)
        • FDT5140 (DC 2-Input Multiply)
        • FDT5150 (DC 2-Input Divide)
      • Temperature
        • Thermocouple
          • FDT5210 (Linearized)
        • RTD
          • FDT5400 (Platinum, Copper, Nickel)
      • Strain Gauge
        • FDT5500 (Bridge Input)
      • AC Input
        • FDT5600 (Standard)
        • FDT5610 (True RMS)
      • Potentiometer
        • FDT5800
  • Custom
    • Custom & OEM
    • Specials/Mods
    • MiniSystems
    • Control Panels
  • Alarms
    • Single
      • DC Input
        • JH1005 (4/20mA w/loop supply)
        • JH1000 (Standard)
      • Temperature
        • Thermocouple
          • JH1200
        • RTD
          • JH1400 (Platinum, Copper, Nickel)
      • Strain Gauge
        • JH1500 (Bridge Input)
      • AC Input
        • JH1600
        • JH1600R (True RMS)
      • Frequency
        • JH1700
      • Potentiometer
        • JH1800
    • Dual
      • DC Input
        • JH1020 (Standard)
        • JH1025 (4/20mA w/loop supply)
      • Temperature
        • Thermocouple
          • JH1220
        • RTD
          • JH1420 (Platinum, Copper, Nickel)
      • Strain Gauge
        • JH1520 (Bridge Input)
      • AC Input
        • JH1620
        • JH1620R (True RMS)
      • Frequency
        • JH1720
      • Potentiometer
        • JH1820
  • Accessories
  • Application Notes
  • Product Listing
  • Blog
  • Contact
Tuesday, 31 May 2011 02:21 Last Updated on Monday, 29 August 2011 01:24 Written by Administrator

JH2376 - Isolated Pulse Conditioner

    • Operates with inputs from DC to 40kHz
    • Conditions Tachometers, Turbines, Power, VFD's, others
    • 5V logic pulse output equals input frequency
    • Inputs from 20mV pk-pk to 250Vrms (700V pk-pk)
    • Full isolation protects against ground loop & safety hazards
    • Adjustable sensitivity, optional filtering
    • Full Replacement Warranty

    JH2376
    PDF
    DATA SHEET

    JH2376
    PDF
    MANUAL

Model JH2376 pulse conditioner accepts a wide range of input voltages and waveforms and produces an isolated 5 volt logic pulse output at the same frequency. It may be used to isolate and condition signals ranging from millivolt-level magnetic pickups to 230Vac power frequencies. No calibration is needed - the output frequency automatically equals the input.

Two sets of input connections support a wide range of applications. The low input connection is optimized for sensors such as magnetic coil tachometer and turbine meter pickups, while high level applications such as power monitoring and variable frequency drives use the high input. (Use the high input for logic pulses.) Adjustable sensitivity, built-in hysteresis and optional filtering minimize interference from noise pickup. Applications range from turbine flow sensors and tachometers to power monitoring and other high voltage applications.

The one-inch-wide case snaps onto DIN rail. The terminal strip unplugs for ease of replacement. The JH2376 handles input frequencies from DC to 40kHz (0.2Hz minimum on high input). When used in high humidity or dirty environments, optional urethane circuit board coating is available.

ORDERING INFORMATION

Model Number:  JH2376A (DC power is not available on this model)
Urethane Coating:  Specify Option U

INSTALLATION AND CONNECTIONS

Model JH2376 snaps onto 35mm DIN rail. Connections are made to the front-panel terminals. The terminal unplugs to facilitate testing or replacing the instrument.

Connections to the 8 terminals (top to bottom) are:

1:  High voltage positive input (generally above 1 volt - see specs).
2:  Input common (for both high and low voltages).
3:  Low voltage positive input (generally below 1 volt - see specs).
4:  Optional filter. Connect terminals 4 & 2 together to activate the filter.
5:  Pulse output (plus).
6:  Pulse output common.
7:  AC power.
8:  AC power.

DETAILED SPECIFICATIONS

High Inputs (Terminals 1 & 2):  For inputs generally above 1 volt (maximum 250Vrms or +/- 350V peak) with frequencies between 0.2Hz and 40kHz. Capacitively coupled - no response to DC. 1 megohm input impedence. See manual for detailed frequency range sensitivities.
Low Inputs (Terminals 3 & 2):  For inputs generally below 1 volt (maximum +/- 100V peak) with frequencies ranging from DC to 40kHz. Input must swing both plus and minus with no DC bias or offset. 50kohm input impedence. See manual for detailed frequency range sensitivities.
Input Sensitivity Adjustment:  25 turn trimpot. Full clockwise - max. sensitivity (see detailed table in manual for sensitivities by frequency range). Full ccw reduces sensitivity (increases the required input) approximately 10:1.
Optional Input Filter:  Connect terminals 4 & 2 together. Recommended for use with magnetic coil tachometer pickups and other sensors whose output amplitudes increase with frequency. Also useful to reduce high frequency noise pickup
Output:  0/+5V logic pulse. Output frequency equals the input. Pulse width and duty cycle will vary with input frequency, amplitude and waveform, but the frequency will not be affected. The output is in phase with (same polarity as) the input.
Isolation:  3-way (input/output/power) 1,500Vac rms (2,100V peak).
Operating Temperature:  -10 to +60˚C (-40 to +140˚F).
Power Requirements:  115 or 230Vac, 50/60Hz, 2.5V-A
Email Newsletter icon, E-mail Newsletter icon, Email List icon, E-mail List icon Sign up for our Email Newsletter

Latest News

  • Transmitters with 1 millisecond response time
  • Custom Designs
  • Home
  • Simple Special: Y = 1/X
  • Model JH2376 Pulse Conditioner
JH TECHNOLOGY, INC.  4233 Clark Rd, Unit 9 Sarasota, FL  34233  USA
Toll Free 800-808-0300  Local 941-927-0300  Fax 941.925.8774