• Home
  • Transmitters
    • DIN RAIL
      • DC Input
        • JH5000 (Spans greater than 1V)
        • JH5070 (Spans less than 1V)
        • JH5030 (4/20mA in)
        • JH5040 (4/20mA w/loop supply)
        • JH5050 (4/20mA isolator)
        • JH5060 (other Current inputs)
        • JH5080 (rangeable)
      • Math(Logic)
        • JH5110 (DC 2-Input Add)
        • JH5120 (DC 3-Input Add)
        • JH5130 (DC 2-Input Subtract)
        • JH5140 (DC 2-Input Multiply)
        • JH5150 (DC 2-Input Divide)
        • JH5160 (DC Square)
        • JH5170 (DC Square Root)
      • Temperature
        • Thermocouple
          • JH5200 (Standard)
          • JH5210 (Linearized)
        • RTD
          • JH5400 (Platinum, Copper, Nickel)
      • Strain Gauge
        • JH5500 (Bridge Input)
      • AC Input
        • JH5600 (Standard)
        • JH5610 (True RMS)
      • Frequency
        • JH5700
      • Potentiometer
        • JH5800
    • PLUG-IN
      • DC Input
        • JH4300 (Voltage & Current)
        • JH4300C (4/20mA Isolator)
        • JH4305 (4/20mA w/loop supply)
        • JH4380W (Rangeable)
      • Math(Logic)
        • JH440xI (Add or Subtract)
          • JH4400I: Output = (A+B+C+D)/4
          • JH4401I: Output = (A+B+C)/3
          • JH4402I: Output = (A+B)/2
          • JH4408I: Output = A-B
        • JH4410I (DC Multiply)
        • JH4420I (DC Divide)
        • JH4430I (DC Square)
        • JH4440I (DC Square Root)
      • Temperature
        • Thermocouple
          • JH4130 (Standard)
          • JH4130L (Linearized)
        • RTD
          • JH4001I (Platinum, Copper, Nickel)
      • Strain Gauge
        • JH4051I (Bridge Input)
      • AC Input
        • JH6010I (Voltage)
        • JH6010IR (True RMS Voltage)
        • JH6020I (Current)
        • JH6020IR (True RMS Current)
      • Frequency
        • JH7010I
      • Potentiometer
        • JH4003I
    • Two Wire
      • DC Input
        • JH200
      • Thermocouple
        • JH220 (Fixed)
        • JH225 (Rangeable)
      • RTD
        • JH240 (Fixed)
        • JH245 (Rangeable)
      • Potentiometer
        • JH250
    • Pulse & Frequency
      • Integrator
        • JH7500 (DC to Frequency)
        • JH7501 (DC to Low Pulse/Relay Out)
      • Transmitter
        • JH7580 (Rangeable, Plug-In)
        • JH7010I (Fixed, Plug-In)
        • JH5700 (Fixed, DIN Rail)
      • Alarm
        • JH1700 (Single)
        • JH1720 (Dual)
      • Pulse
        • Amplifier
          • JH376 (Dual Channel)
        • Converter
          • JH377 (Dual Channel)
        • Conditioner
          • JH2376 (Full Feature, DIN Rail)
    • Field Mount Transmitters
      • DC Input
        • FDT5000 (Spans greater than 1V)
        • FDT5070 (Spans less than 1V)
        • FDT5030 (4/20mA in)
        • FDT5040 (4/20mA w/loop supply)
        • FDT5060 (other Current inputs)
      • Math(Logic)
        • FDT5110 (DC 2-Input Add)
        • FDT5120 (DC 3-Input Add)
        • FDT5130 (DC 2-Input Subtract)
        • FDT5140 (DC 2-Input Multiply)
        • FDT5150 (DC 2-Input Divide)
      • Temperature
        • Thermocouple
          • FDT5210 (Linearized)
        • RTD
          • FDT5400 (Platinum, Copper, Nickel)
      • Strain Gauge
        • FDT5500 (Bridge Input)
      • AC Input
        • FDT5600 (Standard)
        • FDT5610 (True RMS)
      • Potentiometer
        • FDT5800
  • Custom
    • Custom & OEM
    • Specials/Mods
    • MiniSystems
    • Control Panels
  • Alarms
    • Single
      • DC Input
        • JH1005 (4/20mA w/loop supply)
        • JH1000 (Standard)
      • Temperature
        • Thermocouple
          • JH1200
        • RTD
          • JH1400 (Platinum, Copper, Nickel)
      • Strain Gauge
        • JH1500 (Bridge Input)
      • AC Input
        • JH1600
        • JH1600R (True RMS)
      • Frequency
        • JH1700
      • Potentiometer
        • JH1800
    • Dual
      • DC Input
        • JH1020 (Standard)
        • JH1025 (4/20mA w/loop supply)
      • Temperature
        • Thermocouple
          • JH1220
        • RTD
          • JH1420 (Platinum, Copper, Nickel)
      • Strain Gauge
        • JH1520 (Bridge Input)
      • AC Input
        • JH1620
        • JH1620R (True RMS)
      • Frequency
        • JH1720
      • Potentiometer
        • JH1820
  • Accessories
  • Application Notes
  • Product Listing
  • Blog
  • Contact
Friday, 10 June 2011 18:21 Last Updated on Monday, 22 August 2011 01:30 Written by Administrator

FDT5600 SERIES FIELD MOUNT TRANSMITTERS AC INPUT

FDT5600: AC Input, Average Responding 
FDT5610: AC Input with True RMS Response

  • NEMA 4X Splashproof Enclosure 
  • 3-1/2 Digit Display 
  • Inputs from 50mV to 250Vrms, 1mA to 5 Amps 
  • True-RMS Response Option Available 
  • Expanded Input Ranges Available 
  • Urethane-Coated Circuit Boards 
  • AC or DC Power Options

FDT5600/FDT5610
PDF
DATA SHEET

Model FDT5600 and FDT5610 AC Input Transmitters provide an isolated DC output proportional to an AC voltage or current input. Input/output isolation is standard to guard against shock hazards in power measurements and against ground loop errors. Inputs ranges may be zero based or may be expanded (for example, 50-150Vac).

A rugged NEMA 4X splashproof, corrosion-resistant housing protects the transmitter in outdoor and industrial environments. The circuit boards are urethane coated for protection against condensation and contaminants. FDT5600 Series transmitters include a 3-1/2 digit user-rangeable display to provide local process indication in engineering units.

Model FDT5600 is average responding, calibrated to provide accurate RMS readings with sine wave inputs. Accuracy is better than 0.5% of span, but will be degraded with nonsinusoidal waveforms such as from SCR/Triac speed and power controllers or pulse-modulated motor drives. For accurate readings with nonsinusoidal waveforms use true-RMS responding Model FT5610.

Available options include AC and DC power choices and reverse-acting transmitter (decreasing output with increasing input).

For field mount transmitters without a display, select any plug-in transmitter module plus our ENCL-1 NEMA-4X enclosure. (see Accessories page)

ORDERING INFORMATION

Model Number: 

Specify Model FDT5600 for standard (average responding) or FDT5610 for true-RMS response.

Display: 

Specify display reading at low end and at full scale, including decimal point if required. See "Display Capabilities" specification, below. Note that reverse-acting display is possible - full scale reading downscale from low end. Display may be re-ranged by user.

Power: 

Add suffix A (for example, FDT5600A) for AC power, D for DC power. Specify 115Vac, 230Vac, 12Vdc or 24Vdc.

Input Range: 

Specify any AC voltage or current range allowed by the "Input Capabilities" spec, below.

Output Range: 

Specify any DC voltage or current range allowed by the "Output Capabilities" spec, below.

Reverse-Acting Transmitter (decreasing output with increasing input): 

Change last digit of the model number to 1 (for example, FDT5601A).

Loop-Powered Output: 

4/20mA "current sink" output stage for connection to devices whose inputs provide 24Vdc loop excitation. Change last digit of the model number to 2 (for example, FDT5602A).

Urethane Coating: 

Specify Option U.

Conduit Connection: 

Standard: None. The enclosure has knockouts. Option NPT: Single 1/2 inch NPT fitting (glass-fiber reinforced nylon) at the bottom of the housing.

ELECTRICAL CONNECTIONS

Connections are made to 8 terminals within the enclosure:

1: AC signal input. 
2: AC signal input. 
3: No connection. 
4: No connection. 
5: Output plus. 
6: Output minus. 
7: Power (AC or, if DC power option, DC plus). 
8: Power (AC or, if DC power option, DC minus).

TRUE-RMS OPTION

Model FDT5600 uses average-responding AC/DC converter circuitry calibrated for RMS sine wave response. Pure AC power and other sine wave inputs will be highly accurate. Nonsinusoidal waveforms, however, such as from SCR/Triac power controllers or variable speed drives (pulsed), will produce appreciable errors.

True-rms response, Model FDT5610, gives correct readings regardless of the waveform's shape.

DETAILED SPECIFICATIONS

Voltage Input Capabilities: 

50mV rms minimum span, 250V maximum input (to 600V rms on special order). Offset ranges are allowed. (Input Impedance: 200kohms or greater.)

Current Input Capabilities: 

1mA rms minimum span, 5 Amps maximum input. Offset ranges are allowed. (Input voltage drop typically 0.1V at full scale. For exact specification for your range, contact factory.)

Input Frequency: 

40 Hz to 1kHz for specified accuracy.

Voltage Output Capabilities: 

1 volt minimum output span, -10 to +15V absolute limit. Offset ranges are allowed. Maximum output load, 10mA (1Kohm at 10V output).

Current Output Capabilities: 

1mA minimum output span, 0 to +25mA absolute limit. Positive offsets are allowed, negative outputs are not. Output drive capability, 24V (1,200 ohms max. at 20mA output).

Display Capabilities: 

Low end and full scale readings may be anywhere between -1999 and +1999 counts. A fixed decimal point may be added in any position. Minimum span (full scale minus low end) is 10 counts. Reverse-acting display is possible (full scale reading downscale from low end). Display may be re-ranged by user.

Accuracy (factory calibration): 

+/-0.5% of span or better.

Adjustability: 

Zero and span each are adjustable approx. +/-15% of span.

Response Time: 

Under 200 milliseconds.

Isolation: 

3-way (Power/Input/Output) 1,500Vac rms (2,100V peak).

Guaranteed Operating Temperature: 

-10 to +60˚C (14 to 140˚F).

Temperature Stability: 

+/-0.02% per ˚C, or better.

Power Requirements: 

AC, 115 or 230Vrms, 50/60Hz, 2.5V-A. DC, 12 or 24V, 2.5W.

Email Newsletter icon, E-mail Newsletter icon, Email List icon, E-mail List icon Sign up for our Email Newsletter

Latest News

  • Home
  • Transmitters with 1 millisecond response time
  • Custom Designs
  • Simple Special: Y = 1/X
  • Model JH2376 Pulse Conditioner
JH TECHNOLOGY, 5107 Lena Rd, Unit 111 Bradenton, FL  34211  USA
Toll Free 800.808.0300  Local 941.758.7710  Fax 941.758.7709