• Home
  • Transmitters
    • DIN RAIL
      • DC Input
        • JH5000 (Spans greater than 1V)
        • JH5070 (Spans less than 1V)
        • JH5030 (4/20mA in)
        • JH5040 (4/20mA w/loop supply)
        • JH5050 (4/20mA isolator)
        • JH5060 (other Current inputs)
        • JH5080 (rangeable)
      • Math(Logic)
        • JH5110 (DC 2-Input Add)
        • JH5120 (DC 3-Input Add)
        • JH5130 (DC 2-Input Subtract)
        • JH5140 (DC 2-Input Multiply)
        • JH5150 (DC 2-Input Divide)
        • JH5160 (DC Square)
        • JH5170 (DC Square Root)
      • Temperature
        • Thermocouple
          • JH5200 (Standard)
          • JH5210 (Linearized)
        • RTD
          • JH5400 (Platinum, Copper, Nickel)
        • Thermistor
      • Strain Gauge
        • JH5500 (Bridge Input)
      • AC Input
        • JH5600 (Standard)
        • JH5610 (True RMS)
      • Frequency
        • JH5700
      • Potentiometer
        • JH5800
    • PLUG-IN
      • DC Input
        • JH4300 (Voltage & Current)
        • JH4300C (4/20mA Isolator)
        • JH4305 (4/20mA w/loop supply)
        • JH4380W (Rangeable)
      • Math(Logic)
        • JH440xI (Add or Subtract)
          • JH4400I: Output = (A+B+C+D)/4
          • JH4401I: Output = (A+B+C)/3
          • JH4402I: Output = (A+B)/2
          • JH4408I: Output = A-B
        • JH4410I (DC Multiply)
        • JH4420I (DC Divide)
        • JH4430I (DC Square)
        • JH4440I (DC Square Root)
      • Temperature
        • Thermocouple
          • JH4130 (Standard)
          • JH4130L (Linearized)
        • RTD
          • JH4001I (Platinum, Copper, Nickel)
        • Thermistor
      • Strain Gauge
        • JH4051I (Bridge Input)
      • AC Input
        • JH6010I (Voltage)
        • JH6010IR (True RMS Voltage)
        • JH6020I (Current)
        • JH6020IR (True RMS Current)
      • Frequency
        • JH7010I
      • Potentiometer
        • JH4003I
    • Two Wire
      • DC Input
        • JH200
      • Thermocouple
        • JH220 (Fixed)
        • JH225 (Rangeable)
      • RTD
        • JH240 (Fixed)
        • JH245 (Rangeable)
      • Potentiometer
        • JH250
    • Pulse & Frequency
      • Integrator
        • JH7500 (DC to Frequency)
        • JH7501 (DC to Low Pulse/Relay Out)
      • Transmitter
        • JH7580 (Rangeable, Plug-In)
        • JH7010I (Fixed, Plug-In)
        • JH5700 (Fixed, DIN Rail)
      • Alarm
        • JH1700 (Single)
        • JH1720 (Dual)
      • Pulse
        • Amplifier
          • JH376 (Dual Channel)
        • Converter
          • JH377 (Dual Channel)
        • Conditioner
          • JH2376 (Full Feature, DIN Rail)
    • Field Mount Transmitters
      • DC Input
        • FDT5000 (Spans greater than 1V)
        • FDT5070 (Spans less than 1V)
        • FDT5030 (4/20mA in)
        • FDT5040 (4/20mA w/loop supply)
        • FDT5060 (other Current inputs)
      • Math(Logic)
        • FDT5110 (DC 2-Input Add)
        • FDT5120 (DC 3-Input Add)
        • FDT5130 (DC 2-Input Subtract)
        • FDT5140 (DC 2-Input Multiply)
        • FDT5150 (DC 2-Input Divide)
      • Temperature
        • Thermocouple
          • FDT5210 (Linearized)
        • RTD
          • FDT5400 (Platinum, Copper, Nickel)
      • Strain Gauge
        • FDT5500 (Bridge Input)
      • AC Input
        • FDT5600 (Standard)
        • FDT5610 (True RMS)
      • Potentiometer
        • FDT5800
  • Custom
    • Custom & OEM
    • Specials/Mods
    • MiniSystems
    • Control Panels
  • Alarms
    • Single
      • DC Input
        • JH1005 (4/20mA w/loop supply)
        • JH1000 (Standard)
      • Temperature
        • Thermocouple
          • JH1200
        • RTD
          • JH1400 (Platinum, Copper, Nickel)
        • Thermistor
      • Strain Gauge
        • JH1500 (Bridge Input)
      • AC Input
        • JH1600
        • JH1600R (True RMS)
      • Frequency
        • JH1700
      • Potentiometer
        • JH1800
    • Dual
      • DC Input
        • JH1020 (Standard)
        • JH1025 (4/20mA w/loop supply)
      • Temperature
        • Thermocouple
          • JH1220
        • RTD
          • JH1420 (Platinum, Copper, Nickel)
        • Thermistor
      • Strain Gauge
        • JH1520 (Bridge Input)
      • AC Input
        • JH1620
        • JH1620R (True RMS)
      • Frequency
        • JH1720
      • Potentiometer
        • JH1820
  • Accessories
  • Application Notes
  • Product Listing
  • Blog
  • Contact
Transmitters Field Mount Transmitters

FDT5000 SERIES FIELD MOUNT TRANSMITTERS

NEMA 4X SPLASH PROOF ENCLOSURES                                        

USER-RANGEABLE  DISPLAY                                            

WIDE SELECTION OF INPUTS AND OUTPUTS

   NONSTANDARD RANGES AVAILABLE

                         INPUT/OUTPUT ISOLATION IS STANDARD

                                URETHANE-COATED CIRCUIT BOARDS

                                                       AC AND DC POWER OPTIONS AVAILABLE

FDT5000 Series field mount transmitters put our proven, reliable circuitry in a rugged, splashproof/corrosion-resistant NEMA-4X enclosure for outdoor and industrial applications. A 3-1/2 digit user-rangeable display facilitates local process indication in engineering units.

Available models cover most standard transducers and inputs, from thermocouple and millivolt signals to AC or DC power. DC add, subtract, multiply and divide functions are available. Output capabilities include standards such as 4-20 or 0-1mA, 0-5, 0-10 and –5/+5V, but we’re equally able to provide “oddball” ranges. Input/output/power isolation is standard.

All models use stable, proven circuitry for accurate measurements under varying ambient conditions. AC and DC power choices are available, as are reverse-acting transmitter and display (decreasing output reading with increasing input). The circuit boards are conformal coated for protection against condensation and contaminants.

A list of model numbers, input styles and options follows. For specifics on the style you need click on the model number in the chart below.

Note: For field mount transmitters without displays, simply mount our plug-in transmitters inside our ENCL-1 NEMA 4X enclosure.

 

INPUT STYLE                               MODEL      

 DC INPUTS:

DC Voltage Input: Spans 1V or wider      FDT5000
4/20mA Input FDT5030
4/20mA Input with loop excitation supply   FDT5040
DC Current Inputs (except 4/20mAdc) FDT5060
DC Millivolt Inputs: spans less than 1V FDT5070
MATH FUNCTIONS (DC Inputs)
2-Input Adder: Output proportional to (A+B)/2 FDT5110
3-Input Adder: Output proportional to (A+B+C)/3 FDT5120
Subtractor: Output proportional to (A-B) FDT5130
Multiplier: Output proportional to A x B FDT5140
Divider: Output proportional to A/B FDT5150

OTHER INPUTS

Thermocouple Input FDT5210
RTD Input, 100 ohm Platinum, Linearized FDT5400
RTD, other (contact factory) FDT54x0
Strain Gauge (Bridge) Input FDT5500
AC Input FDT5600
AC Input, True RMS Response FDT5610
Potentiometer Input FDT5800
(Reserved for specials. Let us know what you need.) FDT5900
Email Newsletter icon, E-mail Newsletter icon, Email List icon, E-mail List icon Sign up for our Email Newsletter

Latest News

  • Home
  • Transmitters with 1 millisecond response time
  • Custom Designs
  • Simple Special: Y = 1/X
  • Model JH2376 Pulse Conditioner
JH TECHNOLOGY, 5107 Lena Rd, Unit 111 Bradenton, FL  34211  USA
Toll Free 800.808.0300  Local 941.758.7710  Fax 941.758.7709