FT5600 SERIES FIELD MOUNT TRANSMITTERS AC INPUT

FT5600: AC Input, Average Responding
FT5610: AC Input with True RMS Response
- NEMA 4X Splashproof Enclosure
- Optional 3-1/2 Digit Display
- Inputs
from 50mV to 250Vrms, 1mA to 5 Amps
- True-RMS Response Option Available
- Expanded Input Ranges Available
- Urethane-Coated Circuit Boards
- AC or DC
Power Options
|
FT5600/FT5610
PDF
DATA SHEET |
Model FT5600 and FT5610 AC Input Transmitters provide an isolated DC output
proportional to an AC voltage or current input. Input/output isolation is
standard to guard against shock hazards in power measurements and against ground
loop errors. Inputs ranges may be zero based or may be expanded (for example,
50-150Vac).
A rugged NEMA 4X splashproof, corrosion-resistant housing protects the
transmitter in outdoor and industrial environments. The circuit boards are
urethane coated for protection against condensation and contaminants. FDT5600
Series transmitters include a 3-1/2 digit user-rangeable display to provide
local process indication in engineering units.
Model FT5600 is average responding, calibrated to provide accurate RMS
readings with sine wave inputs. Accuracy is better than 0.5% of span, but will
be degraded with nonsinusoidal waveforms such as from SCR/Triac speed and power
controllers or pulse-modulated motor drives. For accurate readings with
nonsinusoidal waveforms use true-RMS responding Model FT5610.
Available options include AC and DC power choices and reverse-acting
transmitter (decreasing output with increasing input).
ORDERING INFORMATION
|
Model Number:
|
Specify Model FT5600 for standard (average responding) or
FT5610 for true-RMS response.
|
|
Optional Display:
|
Change FT to FDT (for example, FDT5600). Specify display
reading at low end and at full scale, including decimal point if required. See
"Display Capabilities" specification, below. Note that reverse-acting
display is possible - full scale reading downscale from low end. Display may be
re-ranged by user.
|
|
Power:
|
Add suffix A (for example, FT5600A) for AC power, D for DC power.
Specify 115Vac, 230Vac, 12Vdc or 24Vdc.
|
|
Input Range:
|
Specify any AC voltage or current range allowed by the
"Input Capabilities" spec, below.
|
|
Output Range:
|
Specify any DC voltage or current range allowed by the
"Output Capabilities" spec, below.
|
|
Reverse-Acting Transmitter (decreasing output with increasing input):
|
Change
last digit of the model number to 1 (for example, FT5601A).
|
|
Loop-Powered Output:
|
4/20mA "current sink" output stage for
connection to devices whose inputs provide 24Vdc loop excitation. Change last
digit of the model number to 2 (for example, FDT5602A).
|
|
Urethane Coating:
|
Specify Option U.
|
|
Conduit Connection:
|
Standard: A single 1/2 inch NPT conduit fitting
(glass-fiber reinforced nylon) is provided at the bottom of the housing. Other
options are possible, including no fitting at all. Contact factory
|
ELECTRICAL CONNECTIONS
Connections are made to 8 terminals within the enclosure:
1: AC signal input.
2: AC signal input.
3: No connection.
4: No connection.
5: Output plus.
6: Output minus.
7: Power (AC or, if DC power option, DC plus).
8: Power (AC or, if DC power option, DC minus).
TRUE-RMS OPTION
Model FT/FDT5600 uses average-responding AC/DC converter circuitry calibrated
for RMS sine wave response. Pure AC power and other sine wave inputs will be
highly accurate. Nonsinusoidal waveforms, however, such as from SCR/Triac power
controllers or variable speed drives (pulsed), will produce appreciable errors.
True-rms response, Model FT/FDT5610, gives correct readings regardless of the
waveform's shape.
DETAILED SPECIFICATIONS
|
Voltage Input Capabilities:
|
50mV rms minimum span, 250V maximum input (to
600V rms on special order). Offset ranges are allowed. (Input Impedance:
200kohms or greater.) |
|
Current Input Capabilities:
|
1mA rms minimum span, 5 Amps maximum input.
Offset ranges are allowed. (Input voltage drop typically 0.1V at full scale. For
exact specification for your range, contact factory.)
|
|
Input Frequency:
|
40 Hz to 1kHz for specified accuracy.
|
|
Voltage Output Capabilities:
|
1 volt minimum output span, -10 to +15V absolute
limit. Offset ranges are allowed. Maximum output load, 10mA (1Kohm at 10V
output).
|
|
Current Output Capabilities:
|
1mA minimum output span, 0 to +25mA absolute
limit. Positive offsets are allowed, negative outputs are not. Output drive
capability, 24V (1,200 ohms max. at 20mA output).
|
|
Display Capabilities:
|
Low end and full scale readings may be anywhere between
-1999 and +1999 counts. A fixed decimal point may be added in any position.
Minimum span (full scale minus low end) is 10 counts. Reverse-acting display is
possible (full scale reading downscale from low end). Display may be re-ranged
by user.
|
|
Accuracy (factory calibration):
|
+/-0.5% of span or better.
|
|
Adjustability:
|
Zero and span each are adjustable approx. +/-15% of span.
|
|
Response Time:
|
Under 200 milliseconds.
|
|
Isolation:
|
3-way (Power/Input/Output) 1,500Vac rms (2,100V peak).
|
|
Guaranteed Operating Temperature:
|
-10 to +60oC (14 to 140oF).
|
|
Temperature Stability:
|
+/-0.02% per oC, or better.
|
|
Power Requirements:
|
AC, 115 or 230Vrms, 50/60Hz, 2.5V-A. DC, 12 or 24V, 2.5W.
|