FT5080 FIELD MOUNT TRANSMITTER DC INPUT, RANGEABLE

- NEMA 4X Splashproof Enclosure
- Inputs from 10mV to 220V, 1mA to 100mA
- Outputs from 0/0.5V to -10/+10V, 0/1mA to 0/25mA (Includes 4/20mA)
- Input/Output Isolation Standard · Urethane-Coated Circuit Boards
- AC or DC
Power Options
|
FT5080
PDF
DATA SHEET |
The Model FT5080 User-Rangeable Transmitter provides an isolated DC output
proportional to a DC voltage or current input. Fully user-rangeable, it handles
input voltages from millivolts to over 200 volts and currents to 100mA. Its wide
selection of output ranges includes all common process signals. Applications
include amplifying, reducing, scaling or offsetting DC signals and converting
currents to voltages or voltages to currents.
A rugged NEMA 4X splashproof, corrosion-resistant housing protects the
transmitter in outdoor and industrial environments. The circuit boards are
urethane coated for protection against condensation and contaminants. The
display option is not available on Model FT5080.
Model FT5080 incorporates a low-drift input amplifier for maximum accuracy
when measuring millivolt-level inputs. Input/output isolation eliminates ground
loops and noise problems, and guards against shock hazards when using
high-voltage inputs. Linearity is better than 0.05%. AC and DC power are
available.
ORDERING INFORMATION
| Model Number: |
FT5080 (Display option not available on this model.)
|
| Power: |
Add suffix A (Model FT5080A) for AC power, D for DC power. Specify
115Vac, 230Vac, 12Vdc or 24Vdc.
|
| Factory Settings: |
The FT5080 is normally supplied tested but uncalibrated. If
you wish, specify your desired input and output range on your order and we will
calibrate at no extra charge. Refer to the "Input Capabilities" and
"Output Capabilities" specifications, below.
|
| Conduit Connection: |
Standard: A single 1/2 inch NPT conduit fitting
(glass-fiber reinforced nylon) is provided at the bottom of the housing. Other
options are possible, including no fitting at all. Contact factory
|
| Other Options: |
Please refer to FT5000 Series fixed range transmitters for a
complete selection of options.
|
ELECTRICAL CONNECTIONS
Connections are made to 8 terminals within the enclosure:
1: Input plus. (Also jumper this terminal to terminal 3 for current inputs.)
2: Input minus.
3: Current input plus. (Jumper to terminal 1 for current
inputs.)
4: No connection.
5: Output plus.
6: Output minus.
7: Power (AC or, if
DC power option, DC plus).
8: Power (AC or, if DC power option, DC minus).
DETAILED SPECIFICATIONS
| Input Capabilities: |
Any zero-based voltage range from 0/10mV to 0/220V, or
current range from 0/1 to 0/100mA. Range also may be elevated 25% (such as 1/5V
or 4/20mA) or suppressed 50% (center-zero such as -10/+10V or -1/+1mA.)
|
| Voltage Output Capabilities: |
Standard output ranges include 0/1V, -1/+1V,
0/2V, 0/5V, 1/5V, 0/10V, -10/+10V. Many others are possible.
|
| Current Output Capabilities: |
Standard output ranges include 0/1mA, 1/5mA,
0/10mA, 0/20mA, 4/20mA. Many others are possible. (Positive current outputs
only.)
|
| Accuracy: |
+/-0.1% of span or 10 microvolts, whichever is greater, if properly
calibrated using precision instruments.
|
| Linearity: |
+/-0.05% of span or better.
|
| Response Time: |
Under 100 milliseconds.
|
| Isolation: |
3-way (Power/Input/Output) 1,500Vac rms (2,100V peak).
|
| Guaranteed Operating Temperature: |
-10 to +60oC (14 to 140oF).
|
| Temperature Stability: |
+/-(0.02% of span plus 1.3 microvolts) per oC, or
better.
|
| Power Requirements: |
AC, 115 or 230Vrms, 50/60Hz, 2.5V-A. DC, 12 or 24V, 2.5W.
|
|