FT5000 SERIES FIELD MOUNT TRANSMITTERS DC INPUT, FIXED RANGE

FT5000: DC Voltage Inputs, 1V or Greater
FT5030: DC 4/20mA Input
FT5060: DC Current Inputs (except 4/20mA)
FT5070: DC Millivolt Inputs, less than 1V
- NEMA 4X Splashproof Enclosure
-
Optional 3-1/2 Digit Display
-
Input Ranges from 4mV to 250Volts, 1mA to 5 Amps
-
Nonstandard Ranges Available
- Input/Output Isolation is Standard
-
Urethane-Coated Circuit Boards
- AC or DC Power Options
|
FT5000/FT5030
FT5060/FT5070
PDF
DATA SHEET |
Also see:
FT5040: 4/20mA Input with Loop Excitation Supply
FT5080: User-Rangeable DC Transmitter
FT5000 Series Field Mount Transmitters provide an isolated DC output proportional to a
DC voltage or current input. They are useful for amplifying, reducing, scaling
or offsetting signals, for eliminating ground loops and noise problems and for
converting currents to voltages or vice-versa. The model numbers listed below
reflect a variety of input choices but all share the same basic circuitry,
features and specifications.
A rugged NEMA 4X splashproof, corrosion-resistant housing protects the transmitter
in outdoor and industrial environments. The circuit boards are urethane coated
for protection against condensation and contaminants. FDT5000 Series
transmitters include a 3-1/2 digit user-rangeable display to provide local
process indication in engineering units.
Model
FT/FDT5070 incorporates a low-drift amplifier for millivolt-level inputs. All
models use stable, proven circuitry for accurate measurements under varying
ambient conditions. Available options include AC and DC power choices and
reverse-acting transmitter (decreasing output with increasing input).
ORDERING INFORMATION
|
Model Number:
|
Select from the above list according to your input range. Add suffix A (for example,
FT5000A) for AC power, D for DC power.
|
| Optional Display: |
Change FT to FDT (for example, FDT5000A). Specify display reading at low end and at
full scale, including decimal point if required. See "Display
Capabilities" specification, below. Note that reverse-acting display is
possible – full scale reading downscale from low end. Display may be re-ranged
by user. |
| Input Range: |
Specify any DC voltage or current range allowed by the “Input Capabilities” spec,
below. |
| Output Range: |
Specify any DC voltage or current range allowed by the “Output Capabilities” spec,
below. |
| Power: |
Specify
115Vac, 230Vac, 12Vdc or 24Vdc. |
| Reverse-Acting
Transmitter(decreasing output with increasing input): |
Change last digit of the model number to 1 (for example, FT5001A). |
| Loop-Powered Output: |
4/20mA “current sink” output stage for connection to devices whose inputs provide
24Vdc loop excitation. Change the last digit of the model number to 2 (for
example, FT5002A). |
| Conduit Connection: |
Standard: A single 1/2 inch NPT conduit fitting (glass-fiber reinforced nylon)
is provided at the bottom of the housing. Other options are possible, including no fitting
at all. Contact factory. |
ELECTRICAL CONNECTIONS
Connections are made to 8 terminals within the enclosure:
1: Input plus.
2: Input minus.
3: No connection
4: No connection.
5: Output plus.
6: Output minus.
7: Power (AC or, if DC power option, DC plus).
8: Power (AC or, if DC power option, DC minus).
DETAILED SPECIFICATIONS
| Input Capabilities, Model FT/FDT5000: |
1V minimum span, +/-250V maximum input. Offset ranges are allowed. (Input
Impedance: 200kohms or greater). |
Input Range,
Model FT/FDT5030: |
4/20mAdc. (62 ohms input resistance. 1.25V drop at full scale.) |
|
Input Capabilities, Model FT/FDT5060:
|
1mA minimum span, +/-5 Amps maximum input. Offset ranges are allowed. (Input voltage
drop typically 0.1V at full scale.)
|
|
Input Capabilities,
Model FT/FDT5070:
|
4mV minimum span, 1V maximum span (specify JH5000 for spans greater than 1V.) Offset
ranges are allowed. (Input Impedance: 200kohms or greater.)
|
|
Voltage Output Capabilities:
|
1 volt minimum output span, -10 to +15V absolute limit. Offset ranges are allowed.
Maximum output load, 10mA (1Kohm at 10V output).
|
|
Current Output Capabilities:
|
1mA minimum output span, 0 to +25mA absolute limit. Positive offsets are allowed,
negative outputs are not. Output drive capability, 24V (1,200 ohms max. at 20mA
output).
|
|
Display Capabilities:
|
Low end and full scale readings may be anywhere between -1999 and +1999 counts. A
fixed decimal point may be added in any position. Minimum span (full scale minus
low end) is 10 counts. Reverse-acting display is possible (full scale reading
downscale from low end). Display may be re-ranged by user.
|
|
Accuracy(factory calibration):
|
+/-0.1% of span or 10 microvolts, whichever is greater.
|
|
Adjustability:
|
Zero and span each are adjustable approx. +/-15% of span.
|
|
Linearity:
|
+/-0.05% of span or better.
|
|
Response Time:
|
Under 100 milliseconds.
|
|
Isolation:
|
3-way (Power/Input/Output) 1,500Vac rms (2,100V peak).
|
|
Guaranteed Operating Temperature:
|
-10 to +60oC (14 to 140oF).
|
|
Temperature Stability:
|
+/-(0.02% of span plus 1.3 microvolts) per oC, or better.
|
|
Power Requirements:
|
AC, 115 or 230Vrms, 50/60Hz, 2.5V-A. DC, 12 or 24V, 2.5W. |
|