JH5500 STRAIN GAUGE TRANSMITTER
DIN-RAIL MOUNT, FIXED RANGE

- Input Spans as low as 0.4mV/V
- Excitation Adjustable from 4 to 12V
- Quick-Check Red/Green Output LEDs
- DIN-Rail Mount, 1 Inch Wide
- Unpluggable Terminal Strip
- AC or DC Power Options
|
JH5500
PDF
DATA SHEET |
The Model JH5500 Strain Gauge Transmitter supplies excitation to a strain
gauge or other resistance bridge, amplifies the bridge voltage and provides a
proportional, isolated DC voltage or current output. A low-drift input amplifier
maintains accurate readings under varying ambient conditions.
Red-green Quick-Check LEDs give a quick indication of the relative output.
Red is brighter at the low end, green at high, while at mid-scale both are
approximately equal. Red-only indicates offscale low while green-only indicates
offscale high.
Available options include AC and DC power choices and reverse-acting
transmitter (decreasing output with increasing input).
ORDERING INFORMATION
| Model Number: |
Specify Model JH5500A for AC power,
JH5500D for DC power. |
| Input Range: |
Specify range required in millvolts
(mV), volts (V) or millivolts per volt (mV/V). For example, with 10V
bridge excitation a range of 0/20mV is the same as 0/2 mV/V. See
Specifications below for input capabilities. Offset input ranges are
allowed. |
| Bridge Excitation: |
Standard setting is 10Vdc.
User-adjustable from 4 to 12Vdc. If you wish a factory setting other
than 10V, please specify on your order. |
| Output Range: |
Specify any DC voltage or current
range allowed by the "Output Capabilities" spec, below. |
| Power: |
Specify 115Vac, 230Vac, 12Vdc or
24Vdc. |
| Reverse-Acting Transmitter
(decreasing output with increasing input): |
Change last digit of the model number
to 1 (for example, JH5501A). |
| Loop-Powered Output: |
4/20mA "current sink" output stage
for connection to devices whose inputs provide 24Vdc loop excitation.
Change the last digit of the model number to 2 (for example, JH5502A). |
| Urethane Coating: |
Specify Option U. |
Model JH5500 snaps onto 35mm DIN rail. Connections are made to the
front-panel terminals. The terminal strip unplugs to facilitate calibrating or
replacing the transmitter.
Connections to the 8 terminals (top to bottom) are:
1: Input plus (bridge output).
2: Input minus (bridge output).
3: Bridge excitation plus.
4: Bridge excitation minus.
5: Output plus.
6: Output minus.
7: Power (AC or, if DC power option, DC plus).
8: Power (AC or, if DC power option, DC minus).
DETAILED SPECIFICATIONS
| Input Capabilities: |
4mV (0.4mV/V at 10V excitation)
minimum span, 10V (1V/V at 10V excitation) maximum. Offset ranges are
allowed. (Input Impedance: 200kohms or greater.) |
| Excitation Voltage: |
Adjustable 4 to 12Vdc. Factory set to
10V unless otherwise specified. 40mA maximum current. (120 ohm bridges
limited to 4.8V excitation or less. 350 ohm bridges ok to 12V.) |
| Voltage Output Capabilities: |
1 volt minimum output span, -10 to
+15V absolute limit. Offset ranges are allowed. Maximum output load,
10mA (1Kohm at 10V output). |
| Current Output Capabilities: |
1mA minimum output span, 0 to +25mA
absolute limit. Positive offsets are allowed, negative outputs are not.
Output drive capability, 24V (1,200 ohms max. at 20mA output). |
| Accuracy (factory calibration): |
+/-0.1% of span or 10 microvolts,
whichever is greater. |
| Adjustability: |
Zero and span each are adjustable
approx. +/-15% of span. |
| Linearity: |
+/-0.05% of span or better. |
| Response Time: |
Under 100 milliseconds. |
| Isolation: |
3-way (Power/Input/Output) 1,500Vac
rms (2,100V peak). |
| Guaranteed Operating Temperature: |
-10 to +60 deg. C (14 to 140 deg. F). |
| Temperature Stability: |
+/-(0.02% of span plus 1.3 microvolts)
per deg. C, or better. |
| Power Requirements: |
AC, 115 or 230Vrms, 50/60Hz, 2.5V-A.
DC, 12 or 24V, 2.5W. |
|