JH5100 SERIES MULTIPLY/DIVIDE TRANSMITTERS
DIN-RAIL MOUNT, FIXED RANGE

JH5140: A x B
JH5150: A/B
- Voltage or Current Inputs and Outputs
- Quick-Check Red/Green Output LEDs
- Nonstandard Ranges Available
- DIN-Rail Mount, 1 Inch Wide
- Unpluggable Terminal Strip
- AC or DC Power Options
|
JH5140/JH5150
PDF
DATA SHEET |
Also see:
JH5110/ JH5120/JH5130
for Add/Subtract functions
JH5140/JH5150 Multiply/Divide Transmitters respond to the product or ratio of
2 DC inputs and provide a proportional, isolated DC output.
Standard calibration calculates the inputs and outputs on a percent-of-span
basis. For example, in a JH5140 multiplying transmitter with 4/20mA inputs and a
0/10V output, when both inputs are at 12mA (50%) the output will be 2.5V (25%).
The equation is: 0.5 x 0.5 = 0.25.
Nonstandard calibrations are available, including dissimilar input ranges and
input-to-output offsets. We also can, as a special, create the function, Output
= (A x B)/C. Contact us with your requirements.
Red-green Quick-Check LEDs give a quick indication of the relative output.
Red is brighter at the low end, green at high, while at mid-scale both are
approximately equal. Red-only indicates offscale low while green-only indicates
offscale high.
Voltage or current inputs and outputs may be chosen: the input and output
ranges need not be the same. Available options include AC and DC power choices
and reverse-acting transmitter (decreasing output with increasing input).
ORDERING INFORMATION
| Model Number: |
Select from the list above according
to your input function. Add suffix A (for example, JH5140A) for AC
power, D for DC power. |
| Input Range: |
Specify any DC voltage or current
range allowed by the "Input Capabilities" spec, below. |
| Output Range: |
Specify any DC voltage or current
range allowed by the "Output Capabilities" spec, below. |
| Power: |
Specify 115Vac, 230Vac, 12Vdc or
24Vdc. |
| Reverse-Acting Transmitter (decreasing
output with increasing input): |
Change last digit of the model number to 1
(for example, JH5141A). |
| Loop-Powered Output: |
4/20mA "current sink" output stage
for connection to devices whose inputs provide 24Vdc loop excitation.
Change last digit of the model number to 2 (for example, JH5142A). |
| Urethane Coating: |
Specify Option U. |
INSTALLATION AND CONNECTIONS
JH5100 Series transmitters snap onto 35mm DIN rail. Connections are made to
the front-panel terminals. The terminal strip unplugs to facilitate calibrating
or replacing the transmitter.
Connections to the 8 terminals (top to bottom) are:
1: Input A (positive).
2: Input common (negative).
3: Input B (positive).
4: No connection.
5: Output positive.
6: Output negative.
7: Power (AC or, if DC power option, DC plus).
8: Power (AC or, if DC power option, DC minus).
DETAILED SPECIFICATIONS
| Voltage Input Capabilities: |
100mV minimum span, +/-20V maximum
input. Offset ranges are allowed. (Input Impedance: 200kohms or
greater.) |
| Current Input Capabilities: |
1mA minimum span, +/-100mA maximum
input. Offset ranges are allowed. |
| Voltage Output Capabilities: |
1 volt minimum output span, -10 to
+15V absolute limit. Offset ranges are allowed. Maximum output load,
10mA (1Kohm at 10V output). |
| Current Output Capabilities: |
1mA minimum output span, 0 to +25mA
absolute limit. Positive offsets are allowed, negative outputs are not.
Output drive capability, 24V (1,200 ohms max. at 20mA output). |
| Accuracy (factory calibration): |
+/-0.2% of span. (For divider, input B must
be greater than 20% of span to achieve rated accuracy.) |
| Adjustability: |
Zero and span each are adjustable approx.
+/-15% of span. |
| Response Time: |
Under 100 milliseconds. |
| Isolation: |
3-way (Power/Input/Output) 1,500Vac rms
(2,100V peak). (The inputs are not isolated from each other.) |
| Guaranteed Operating Temperature: |
-10 to +60 deg. C (14 to 140 deg. F). |
| Temperature Stability: |
+/-0.02% of span per deg. C, or better. |
| Power Requirements: |
AC, 115 or 230Vrms, 50/60Hz, 2.5V-A. DC, 12
or 24V, 2.5W. |
|