• Home
  • Transmitters
    • DIN RAIL
      • DC Input
        • JH5000 (Spans greater than 1V)
        • JH5070 (Spans less than 1V)
        • JH5030 (4/20mA in)
        • JH5040 (4/20mA w/loop supply)
        • JH5050 (4/20mA isolator)
        • JH5060 (other Current inputs)
        • JH5080 (rangeable)
      • Math(Logic)
        • JH5110 (DC 2-Input Add)
        • JH5120 (DC 3-Input Add)
        • JH5130 (DC 2-Input Subtract)
        • JH5140 (DC 2-Input Multiply)
        • JH5150 (DC 2-Input Divide)
        • JH5160 (DC Square)
        • JH5170 (DC Square Root)
      • Temperature
        • Thermocouple
          • JH5200 (Standard)
          • JH5210 (Linearized)
        • RTD
          • JH5400 (Platinum, Copper, Nickel)
        • Thermistor
      • Strain Gauge
        • JH5500 (Bridge Input)
      • AC Input
        • JH5600 (Standard)
        • JH5610 (True RMS)
      • Frequency
        • JH5700
      • Potentiometer
        • JH5800
    • PLUG-IN
      • DC Input
        • JH4300 (Voltage & Current)
        • JH4300C (4/20mA Isolator)
        • JH4305 (4/20mA w/loop supply)
        • JH4380W (Rangeable)
      • Math(Logic)
        • JH440xI (Add or Subtract)
          • JH4400I: Output = (A+B+C+D)/4
          • JH4401I: Output = (A+B+C)/3
          • JH4402I: Output = (A+B)/2
          • JH4408I: Output = A-B
        • JH4410I (DC Multiply)
        • JH4420I (DC Divide)
        • JH4430I (DC Square)
        • JH4440I (DC Square Root)
      • Temperature
        • Thermocouple
          • JH4130 (Standard)
          • JH4130L (Linearized)
        • RTD
          • JH4001I (Platinum, Copper, Nickel)
        • Thermistor
      • Strain Gauge
        • JH4051I (Bridge Input)
      • AC Input
        • JH6010I (Voltage)
        • JH6010IR (True RMS Voltage)
        • JH6020I (Current)
        • JH6020IR (True RMS Current)
      • Frequency
        • JH7010I
      • Potentiometer
        • JH4003I
    • Two Wire
      • DC Input
        • JH200
      • Thermocouple
        • JH220 (Fixed)
        • JH225 (Rangeable)
      • RTD
        • JH240 (Fixed)
        • JH245 (Rangeable)
      • Potentiometer
        • JH250
    • Pulse & Frequency
      • Integrator
        • JH7500 (DC to Frequency)
        • JH7501 (DC to Low Pulse/Relay Out)
      • Transmitter
        • JH7580 (Rangeable, Plug-In)
        • JH7010I (Fixed, Plug-In)
        • JH5700 (Fixed, DIN Rail)
      • Alarm
        • JH1700 (Single)
        • JH1720 (Dual)
      • Pulse
        • Amplifier
          • JH376 (Dual Channel)
        • Converter
          • JH377 (Dual Channel)
        • Conditioner
          • JH2376 (Full Feature, DIN Rail)
    • Field Mount Transmitters
      • DC Input
        • FDT5000 (Spans greater than 1V)
        • FDT5070 (Spans less than 1V)
        • FDT5030 (4/20mA in)
        • FDT5040 (4/20mA w/loop supply)
        • FDT5060 (other Current inputs)
      • Math(Logic)
        • FDT5110 (DC 2-Input Add)
        • FDT5120 (DC 3-Input Add)
        • FDT5130 (DC 2-Input Subtract)
        • FDT5140 (DC 2-Input Multiply)
        • FDT5150 (DC 2-Input Divide)
      • Temperature
        • Thermocouple
          • FDT5210 (Linearized)
        • RTD
          • FDT5400 (Platinum, Copper, Nickel)
      • Strain Gauge
        • FDT5500 (Bridge Input)
      • AC Input
        • FDT5600 (Standard)
        • FDT5610 (True RMS)
      • Potentiometer
        • FDT5800
  • Custom
    • Custom & OEM
    • Specials/Mods
    • MiniSystems
    • Control Panels
  • Alarms
    • Single
      • DC Input
        • JH1005 (4/20mA w/loop supply)
        • JH1000 (Standard)
      • Temperature
        • Thermocouple
          • JH1200
        • RTD
          • JH1400 (Platinum, Copper, Nickel)
        • Thermistor
      • Strain Gauge
        • JH1500 (Bridge Input)
      • AC Input
        • JH1600
        • JH1600R (True RMS)
      • Frequency
        • JH1700
      • Potentiometer
        • JH1800
    • Dual
      • DC Input
        • JH1020 (Standard)
        • JH1025 (4/20mA w/loop supply)
      • Temperature
        • Thermocouple
          • JH1220
        • RTD
          • JH1420 (Platinum, Copper, Nickel)
        • Thermistor
      • Strain Gauge
        • JH1520 (Bridge Input)
      • AC Input
        • JH1620
        • JH1620R (True RMS)
      • Frequency
        • JH1720
      • Potentiometer
        • JH1820
  • Accessories
  • Application Notes
  • Product Listing
  • Blog
  • Contact
Application Notes

AN2301: Split Loops without a Loop Splitter

Use a low-cost single loop 4-20mA isolator to create a second loop.

Products referenced: JH4300C, JH4305, JH5040, JH5050

 

AN2302: Module Provides “Missing Link”

Marrying a field-upgrade 4/20mA sensor to an old, nonstandard voltage-input “legacy” system.

Products referenced: JH4300, JH5000

 

AN2303: How to Safely Connect a Powered Transmitter to a PLC’s 2-Wire Loop Input

“Loop Powered Output” (current sinking) option allows a powered transmitter’s output to look like a 2-wire transmitter.

Products referenced: Most JH Technology AC- or DC-powered transmitters.

 

AN2304: Barriers Safeguard Adjustment in Hazardous Location

Using intrinsic safety barriers to provide safe manual control (potentiometer) in a potentially-explosive area.

Products referenced: JH4003I, JH5800

 

AN2305: Isolator Eases Calibration of Hard-To-Reach Measurement System

A conveniently-located 4-20mA isolator put the zero and span adjustments within easy reach.

Products referenced: JH4300C, JH4305

 

AN2306: AC to DC Translation Monitors Shaker Motion

In an oscillating system, an AC input transmitter converts instantaneous position measurement to a DC signal representing peak-to-peak amplitude.

Products referenced: JH5600, JH6010I

 

AN2307: In-The-Terminal C/J Compensation Maximizes Thermocouple Accuracy

Putting the cold-junction sensor in the connection terminal virtually eliminates compensation errors.

Products referenced: All JH Technology thermocouple transmitters and alarms

 

AN2308: Thermocouple Alarm Distinguished Between Overtemperature and T/C Failure

When properly set up, one relay announces overtemperature while the other warns of thermocouple failure.

Product referenced:JH1220

 

AN2309: Signal Isolator Serves as Subtractor

Subtract two voltage signals using a low-cost isolator.

Products referenced: JH4300, JH5000, FT/FDT5000

 

AN2310: Monitoring Ship’s Throttle Position

Expanded-scale potentiometer transmitter converts throttle position to control voltage in a ship upgrade.

Product referenced: JH4003I

 

AN2601:  Gas Flow Minisystem

A small system of JH Technology modules converts volume flow rate from a turbine meter to mass flow, compensated for pressure and temperature variations.

Products referenced: JH7580, JH4300, JH9046 and two specials.

 

AN11001: True RMS Basics

What is True RMS and when do I need it?

Products referenced: JH5610, JH6010IR, JH6020IR

 

AN11002: True RMS: AC or DC

True RMS: AC or DC response? It depends!

Products referenced: JH5610, JH6010IR, JH6020IR

Email Newsletter icon, E-mail Newsletter icon, Email List icon, E-mail List icon Sign up for our Email Newsletter

Latest News

  • Home
  • Transmitters with 1 millisecond response time
  • Custom Designs
  • Simple Special: Y = 1/X
  • Model JH2376 Pulse Conditioner
JH TECHNOLOGY, 5107 Lena Rd, Unit 111 Bradenton, FL  34211  USA
Toll Free 800.808.0300  Local 941.758.7710  Fax 941.758.7709