DC INPUT PLUG-IN ALARM MODULES

JH1000: Single Trip Alarm
JH1020: Dual Trip Alarm
Models JH1000 and JH1020 DC Input Alarms monitor a DC voltage or current and provide relay
contact HI/LO trip outputs. Both are fixed-range devices, with input ranges preset per your order.
The alarm trip points are adjustable anywhere within the input range. Deadbands also are
fully adjustable, from 0.25% to 100% of span. A slide switch, accessible through the top of the enclosure,
selects HI or LO trip operation (on dual alarms, HI/HI, HI/LO or LO/LO). Red/green LEDs indicate alarm
status.
Alarm contacts are rated at 5 amps, 230Vac or 30Vdc. Model JH1000 provides one set of DPDT
relay contacts; Model JH1020, two SPDT relays. Both models now include as standard a low-drift input
amplifier for millivolt-level signals (formerly an extra-cost option). AC and DC power options are available.
ORDERING INFORMATION
|
Model Number: |
Select JH1000 single-trip alarm or JH1020 dual-trip
alarm. Add suffix –AC for AC power or –DC for DC power.
|
|
Input Range: |
Specify any DC voltage or current range allowed by
the "Input Capabilities" spec, below.
|
|
Trip Point: |
If you would like the trip points to be factory set,
please specify the following for each trip point. Specify HI or LO trip, specify the setpoint and specify the
amount of deadband required (or specify "minimum deadband").
|
|
Relay Action: |
Standard is Failsafe - the relay is
energized under normal conditions and deenergizes upon alarm or upon loss of power. Thus, loss of power is
seen as an alarm condition. Or specify Option R (Reverse Acting) – relay is normally not energized
and energizes (pulls in) upon alarm trip. Failsafe is provided if not specified.
|
|
Power: |
Specify 115Vac, 230Vac, 12Vdc or 24Vdc.
|
|
Urethane Coating: |
Specify Option "U"
|
INSTALLATION AND CONNECTIONS
These alarms plug into any standard 11-pin circular ("octal") relay socket. JH
Technology offers a socket suitable for DIN-rail or surface mounting (see
the Accessories page). Pin connections are:
Pin 1: Power (AC or, if DC power option, DC plus).
Pin 2: No connection.
Pin 3: Power (AC or, if DC power option, DC minus).
Pin 4: Input plus.
Pin 5: Input minus.
Pin 6: Setpoint 1 relay NO contact.*
Pin 7: Setpoint 1 relay moving contact.*
Pin 8: Setpoint 1 relay NC contact.*
Pin 9: Setpoint 2 relay NO contact.*
Pin 10: Setpoint 2 relay moving contact.*
Pin 11: Setpoint 2 relay NC contact.*
- Notes: NO (normally open) and NC (normally closed) refer to the relay state when no power
is applied. For Failsafe operation the NO contacts are closed under nonalarm conditions. The NC contacts
close upon alarm and upon loss of power. The terms Setpoint 1 and Setpoint 2 refer to dual-trip alarms. For
single-trip alarms, both sets of contacts respond to the one trip point.
DETAILED SPECIFICATIONS
|
Voltage Input Capabilities: |
4mV minimum span, +/-250V maximum
input. Offset ranges are allowed. (Input Impedance: 200Kohms or greater.) |
|
Current Input Capabilities: |
1mA minimum span, +/-5 Amps maximum input. Offset ranges are allowed.
(Input Resistance: Varies with input range. Contact factory for details. 62 ohms for 4/20mA input.)
|
|
Relay Contacts: |
Single Alarm, one DPDT relay. Dual Alarm, two
SPDT relays. Contacts rated 5 Amps resistive, 115/230Vac or 30Vdc. 1/8 HP max inductive load at 115/230Vac.
Refer to instructions for contact protection when switching inductive loads.
|
|
Setpoint Adjustment: |
0% to 100% of range.
|
|
Deadband Adjustment: |
0.25% to 100% of range.
|
|
Response Time: |
under 100 milliseconds.
|
|
Isolation: |
Input is isolated from power and from relay contacts.
1,500Vac rms (2,100V peak) breakdown.
|
|
Guaranteed Operating Temperature: |
-10 to +60 deg. C (14 to 140
deg. F).
|
|
Temperature Stability: |
+/-(0.02% of span plus 1.3 microvolts) per
deg. C, or better.
|
|
Power Requirements: |
AC, 115 or 230Vrms, 50/60 Hz., 2.5V-A. DC, 12
or 24Vdc, 2.5W.
|