MODEL JH220: 2-WIRE TRANSMITTER
THERMOCOUPLE INPUT, FIXED RANGE, NONISOLATED

- Available for All Thermocouple Types
- Input Ranges as low as 2mV
- Low-Drift Input Amplifier
- Fits Standard Connection Heads
- -40 to +80 Degree C Operation
|
JH220
PDF
FILE |
The Model JH220 2-wire transmitter provides a 4/20mA current loop output proportional to
the input from a thermocouple. A fixed-range device, it is precisely calibrated to your specified input range
at the factory. (For a rangeable 2-wire thermocouple transmitter see Model JH225.) Span may be as low as 2
millivolts (approximately 50 deg C for type K thermocouple). Cold junction compensation is located in the
terminal block for optimum accuracy. Conformal coating protects the circuitry against condensation and
corrosion in industrial atmospheres. Upscale burnout indication is standard.
The JH220 is a loop-powered device. Connected in series between a 24Vdc supply and readout
instruments, it receives its power from the 4/20mA output loop. A built-in LED indicates loop current: dim at
4mA, bright at 20. The JH220 does not provide input/output isolation.
ORDERING INFORMATION
| Model Number: |
Model JH220.
|
|
Thermocouple Type: |
Specify type J, K, T, E, R, S, B or N, or
contact factory for others.
|
| Input Range: |
Specify any range corresponding to 2mVor higher
span. (4mV equals approx. 50 deg. C for type K thermocouples.)
|
|
T/C Burnout Indication: |
(Always upscale – offscale high.)
|
| Output Range: |
(Always 4/20mAdc.)
|
| Power: |
(Always dc loop powered.)
|
|
DIN-Rail Mounting: |
Change model number to Model JH220-DIN. (See
"Installation and Connections," below.)
|
INSTALLATION AND CONNECTIONS
The JH220 is 1-3/4 inches in diameter and is designed to fit many standard
thermocouple-type connection heads. It may also be mounted to any surface using two #8 (or smaller) screws.
An optional DIN-rail mounting clip (specify Model JH220-DIN) allows the transmitter to be snapped onto DIN
rail. Width is 1-3/4 inches.
Connections are made to the transmitter’s terminal strip. Connections are:
"+" Terminal: Output/Power Loop. Receives current from
(+) DC supply.
"-" Terminal: Output/Power Loop. Passes on current to the next series loop
device, or to the (-) supply.
Terminal A: Thermocouple plus.
Terminal B: No connection –
compensator is encapsulated in this position.
Terminal C: Thermocouple minus. (On most thermocouples,
the red wire is minus.)
DETAILED SPECIFICATIONS
|
Input Capabilities: |
Any input span 2mV or higher. Offset ranges
are allowed.
|
|
Input Thermocouple Type: |
Any standard thermocouple type (J, K, T,
E, R, S, B, N). Others possible –contact factory.
|
|
Thermocouple Burnout Indication: |
Output goes offscale high (above
20mA).
|
|
Output: |
4/20mA, 2-wire (loop-powered) output.
|
|
Accuracy (factory calibration): |
+/-0.1% of span or 10 microvolts,
whichever is greater.
|
| Adjustability: |
Zero and span each are adjustable approx. +/-15%
of span.
|
| Linearity: |
Linear with millivolts. Does not linearize the
thermocouple.
|
| Response Time: |
Under 100 milliseconds.
|
| Guaranteed Operating Temperature: |
-40 to +80 deg. C (-40 to +176
deg. F).
|
| Temperature Stability: |
+/-(0.02% of span plus 1 microvolt) per
deg. C, or better.
|
| Power Requirements: |
DC loop-powered. Requires at least 12Vdc at
the transmitter’s output terminals. 36Vdc maximum.
|